User's Manual
ElectricalTests
Electrical Electrical
Electrical
Tests Tests
Tests
Usethefollowingprocedurestotestthecondition
ofthepowersupplyandgunbody,andelectrical
continuitybetweencomponents.
UsemegohmmeterPartNo.241079(AA)andan
appliedvoltageof500V.Connecttheleadsas
shown.
MegohmmeterPartNo.241079(AA-seeFig.
17)isnotapprovedforuseinahazardousarea.
Toreducetheriskofsparking,donotusethe
megohmmetertocheckelectricalgrounding
unless:
•Thegunhasbeenremovedfromthehazardous
area;
•Orallsprayingdevicesinthehazardousarea
areturnedoff,ventilationfansinthehazardous
areaareoperating,andtherearenoammable
vaporsinthearea(suchasopensolvent
containersorfumesfromspraying).
Failuretofollowthiswarningcouldcausere,
explosion,andelectricshockandresultinserious
injuryandpropertydamage.
Test Test
Test
Gun Gun
Gun
Resistance Resistance
Resistance
1.Flushanddrytheuidpassage.
2.For For
For
Model Model
Model
L40T14 L40T14
L40T14
and and
and
L40T15 L40T15
L40T15
guns guns
guns
only: only:
only:
Test
thebarrelcontinuitytoverifythatthemetalpin
inthebarrelisproperlygrounded.Measure
resistancebetweenthemetalpin(GP)andthe
airswivel(21).Theresistanceshouldbeless
than100ohms.Iftheresistanceis100ohmsor
more,replacethegunbody.
3.For For
For
all all
all
guns: guns:
guns:
Triggerthegunandmeasure
resistancebetweentheelectrodeneedletip(3)
andtheairswivel(21).Theresistanceshouldbe:
•75–120megohmsfor40kVguns
•104–148megohmsfor60kVguns
•148–193megohmsfor85kVguns
Ifoutsidethisrange,testthegun
untriggered.Ifstilloutsidethisrange,goto
TestPowerSupplyResistance,page32.Ifinrange,
seeElectricalTroubleshooting,page35forother
possiblecausesofpoorperformance.
Figure17TestGunResistance
3A2494D 31