User's Manual

GunOverview
Diagnostic Diagnostic
Diagnostic
Mode Mode
Mode
DiagnosticModeincludesfourscreenswhichdisplay
gundata:
Voltage(kiloVolts)Screen
Current(microAmperes)Screen
AlternatorSpeed(Hertz)Screen
LowVoltageLockScreen
NOTE: NOTE:
NOTE:
YoumustbeinOperatingModetoadjustthe
lowvoltagesetting;thesettingisnotadjustablein
DiagnosticMode.However,thevoltageadjustment
switch(VA)canbesettoHIorLOinOperatingMode
andinDiagnosticMode.
ToenterDiagnosticMode,pressandholdtheLOSET
(LS)buttonforapproximately5seconds.Thedisplay
willgototheVoltage(kiloVolts)Screen,page13.
Toadvancetothenextscreen,presstheLOSET
buttonagain.
ToexitDiagnosticMode,pressandholdtheLOSET
buttonforapproximately5seconds.Thescreenwill
returntoOperatingMode.
NOTE: NOTE:
NOTE:
IfthegunisdetriggeredwhileinDiagnostic
Mode,thelastscreenviewedwillbedisplayedwhen
thegunisretriggered.
NOTE: NOTE:
NOTE:
DiagnosticModecannotbeexited
fromtheLowVoltageLockScreen.See
LowVoltageLockScreen,page14fordetails.
Voltage Voltage
Voltage
(kiloVolts) (kiloVolts)
(kiloVolts)
Screen Screen
Screen
TheVoltage(kiloVolts)Screenistherstscreento
appearafterenteringDiagnosticMode.SeeFig.6,
andTable1onpage10.Toenterthisscreen,press
andholdtheLOSETbuttonforapproximately5
secondswhileintheOperatingMode.
Thisscreendisplaysthesprayingvoltageofthe
gunasanumber(kV),roundedtothenearest5kV.
ThetwotoprightLEDs(VI)ofthedisplaypanel
light,indicatingthattheVoltage(kiloVolts)Screen
isdisplayed.Thedisplayisareadoutandcannot
bechanged.
PresstheLOSETbuttontoadvancetothe
Current(microAmperes)Screen,page13.Press
andholdforapproximately5secondstoreturnto
OperatingMode.
Figure6Voltage(kiloVolts)Screen
Current Current
Current
(microAmperes) (microAmperes)
(microAmperes)
Screen Screen
Screen
TheCurrent(microAmperes)Screenisthesecond
screenintheDiagnosticMode.SeeFig.7,andTable
1onpage10.Toenterthisscreen,presstheLO
SETbuttonwhileintheVoltage(kiloVolts)Screen.
Thisscreendisplaysthesprayingcurrentofthegun
asanumber(uA),roundedtothenearest5uA.The
twobottomrightLEDs(CI)ofthedisplaypanellight,
indicatingthattheCurrent(microAmperes)Screen
isdisplayed.Thedisplayisareadoutandcannot
bechanged.
PresstheLOSETbuttontoadvancetothe
AlternatorSpeed(Hertz)Screen,page14.Press
andholdforapproximately5secondstoreturnto
OperatingMode.
Figure7Current(microAmperes)Screen
3A2494D 13