User's Manual

Accessories
3A2347T 99
6 Channel Upgrade Kit Installation
1. Disconnect plug from power outlet or turn off circuit
breaker for incoming power.
2. Place grounding wrist strap (1303) over your wrist
and secure other end to a grounded surface.
3. Set MZLP (1301) rotary switch to “3”.
4. Remove screws (BB) then remove plate (AA) from
system.
5. Use screws (BB) to install MZLP (1301) onto sys-
tem.
6. Remove electrical enclosure front access door.
NOTE: Do not force the electrical connection. Minimal
force is required to seat the connector. If resistance is
felt, stop and verify the connector orientation.
7. Move ADM CAN connector from MZLP 2 connector
J6 to MZLP 3 connector J3. See F
IG
. 58.
8. Connect CAN jumper cable (1302) to MZLP 2 con-
nector J6 and connect other end of jumper
cable (1302) to MZLP 3 connector J6. See F
IG
. 58.
9. Install jumper connector (1307) in J5 on MZLP 3.
10. Connect wires from power harness (1306) to con-
nectors as labeled on the plastic connector.
11. Connect power harness (1306) to MZLP 3 connec-
tor J2.
12. Remove plugs (CC) from fluid manifold and replace
with tee fittings (1308).
NOTE: The new MZLP (1301) will be referred to as
MZLP 3, and the original MZLPs that came with the sys-
tem will be referred to as MZLP 1 and MZLP 2 from here
on. See F
IG
. 58.
F
IG
. 58
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WLD
0=/3
0=/3
0=/3
7R
$'0
Step 8: Install jumper cable (1302).
Step 7: Move ADM CAN connector.