User's Manual

Accessories
3A2347T 95
Light Tower Kit Installation
1. Turn main power switch OFF.
2. Disconnect cable from ADM, push cable through
plastic shroud, then remove shroud from system.
3. Remove existing grommet (AA) from electrical
enclosure then install new grommet (1204) in its
place.
4. Insert grommet (1202) into hole on the light tower
bracket (1203).
5. Remove bolts (BB) from metal shroud on the sys-
tem then use the bolts (BB) to secure
bracket (1203) to metal shroud.
6. Route light tower cable through hole in
bracket (1203) then use supplied light tower
screws (1201a) to install light tower (1201).
7. Remove electrical enclosure front access door.
8. Route light tower cable through the other hole in the
bracket (1203), then through the grommet (1204)
into the electrical enclosure.
9. Connect light tower cable to MZLP connector
labeled J12.
Air Reservoir Kit, 16W366
This kit allows the system to operate as low as 60 psi
(0.4 MPa, 4 bar).
16W366 Parts
--- Not for sale.
* Metric fitting included in Air Metric Fitting Kit,
24W637, page 103.
Ref Part Description Qty
1501 --- HOSE, nylon (6 ft) 1
1502 100081 BUSHING, pipe 1
1503 113777 TEE, branch 1
1504* 114485 CONNECTOR, male, 3/8 npt 2
1505 155665 UNION, adapter 1
1506 --- TANK, air, accumulator 1
1501
1504
1504*
1503
1505
1505
1506