User's Manual
Troubleshooting
3A2347T 45
Slow start-up
time or system
takes longer
than 10 min-
utes to startup
Wrong setting in ADM
breaker setup.
Wrong breaker setting on ADM in the breaker setting in the setup
screen.
Low incoming voltage. Incoming voltage should be 200-240VAC for a 230 volt unit and 380-
400 VAC for a 400 volt unit.
Heater rod defective.
Melter and gun mani-
fold.
Measure and check heater rods in melter or manifold. Manifold resis-
tance 130-140 ohms.
Heated hose defective. Measure heater wires in hose, pins C and D. See repair section for
each hose resistance.
Insufficient power sup-
plied to system.
Depending on hose
and gun combinations,
along with minimal sup-
ply power, startup time
will vary.
Connect system to a power supply capable of maximum power per
system specification. All changes must be performed by a qualified
electrician. See Electrical Schematics on page 72 for details about
connecting to a different power supply.
No adhesive or
little adhesive
being dis-
pensed
Incorrect RTD setting in
system.
1. Verify melter, hose, and manifold temperatures are all with in the
same range of the room ambient.
2. If the manifold temperature is either much higher or much lower than
the melter temperature then the RTD setting is not correct for the
RTD being used. Select correct RTD setting in the setup screen sys-
tem 2 before beginning.
NOTE: Failure to have the correct RTD value will cause the manifold
and gun to either under-heat or over-heat. Setting for RTD in the ADM
screens is higher than actual RTD value. Consult manufacturer for
actual RTD value.
System indi-
cates no errors
and correct
temperature
however mani-
fold and gun
are over the
temperature
setpoint
Incorrect RTD setting in
system.
1. Verify melter, hose, and manifold temperatures are all with in the
same range of the room ambient.
2. If the manifold temperature is either much higher or much lower than
the melter temperature then the RTD setting is not correct for the
RTD being used. Select correct RTD setting in the setup screen sys-
tem 2 before beginning.
NOTE: Failure to have the correct RTD value will cause the manifold
and gun to either under-heat or over-heat. Setting for RTD in the ADM
screens is lower than actual RTD value. Consult manufacturer for
actual RTD value.
Problem Cause Solution