Last Digit in Code Code Relates to:
0Melter
1Gun 1
2 Hose 1
3Gun 2
4 Hose 2
5Gun 3
6 Hose 3
7Gun 4
8 Hose 4
9Gun 5
A Hose 5
BGun 6
C Hose 6
Code Description Type Cause Solution
A4D0 High Current
Melter
Alarm Defective or shorted to ground on
the band heater or rod heater.
Measure resistance to ground between
heater leads. Should be a high reading.
A4D_ High Current
Hose X
Alarm Defective or shorted to ground on
the hose power wires.
Replace heated hose.
A4D_ High Current
Gun X
Alarm Defective or shorted to ground on
the heater rods in gun manifold.
Replace gun manifold.