User's Manual

Maintenance
3A2347T 35
4. When the melter temperature is the desired tem-
perature, turn main power switch OFF.
5. Disconnect cable from ADM, push cable through
plastic shroud, then remove plastic shroud from sys-
tem.
6. Place a piece of cardboard beneath the inlet filter
cap (215) to route fluid away from system into a
waste container in the event the adhesive is a fluid.
7. Use 1 in. socket to remove inlet filter cap (215).
8. If the adhesive is a thin enough gel to remove the
inlet filter: Use an o-ring pick or small allen wrench
to remove filter screen (213) from system.
Otherwise:
a. Install inlet filter cap (215).
b. Install shroud and ADM.
c. Turn main power switch ON.
d. Once ADM software finishes starting up,
press to enable the heaters.
e. Wait for temperature to rise 20°F (11°C) beyond
previous temperature.
f. Go to step 4.
9. Slide new screen (213) into melter base
manifold (201).
10. Install filter cap (215) then use a 1 in. socket to
tighten.
11. Feed ADM cable through plastic shroud (29) then
install shroud onto system. Connect cable to
ADM (30).
Replace Funnel Filter
Disassembly (see F
IG
. 23):
1. Turn main power switch OFF.
2. Loosen and remove the two phillips head
screws (705) on the side of the funnel (706) then
remove the funnel cap (701).
Reassembly (see F
IG
. 23):
1. Place funnel cap (701) onto funnel (706).
2. Install two phillips head screws (705) to secure fun-
nel cap to funnel base.
F
IG
. 22
ti20909a
215
213
201
F
IG
. 23
701
706
ti20927b
705