User's Manual
Operation
30 3A2347T
Enable Schedule Function
The Schedule function is automatically enabled when
values are entered in the Schedule screen. To disable
the Schedule function, delete all values on the Schedule
screen or turn the main power switch OFF to prevent
system from automatically enabling and disabling the
heaters.
How to Use the Schedule Function
At the end of the work day leave main power switch ON
. The Schedule function will automatically enable
and disable the heaters and pump at the specified
times.
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1. Turn main power switch OFF .
2. Close the inlet air supply ball valve.
NOTE: Manually verify the pressure is relieved by open-
ing the gun and ensuring no adhesive is dispensed.
Drain the System
NOTE: The system must be drained prior to flushing
and prior to some maintenance and repair procedures.
1. On the System 3 screen (in the Setup screens),
change the Refill Setting to “Manual”.
2. If the heating system is disabled, press to
enable the heaters and pump.
3. Decrease pump air pressure to 0.
4. Close system air inlet ball valve.
5. Disconnect hose from gun inlet then place hose out-
let in a waste container. Repeat for all hoses. Keep
hose to gun electrical connector connected.
6. Open gun to allow residual fluid in gun to drain.
7. When system is at operating temperature, slowly
increase pump air pressure until fluid begins flowing
into the waste container.
NOTE: It may take several minutes to empty the sys-
tem. When there is no melter fluid at the pump, the
pump will begin to cycle faster.
8. When the pump begins to cycle faster, close the
system air inlet ball valve.
9. Press to disable the heaters and pump.
10. Remove melter drain plug (W1). See F
IG
. 2 on page
9.
11. Disconnect hose from melter outlet.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.










