User's Manual

Operation
3A2347T 29
b. Check pressure gauges (D, F) to verify vacuum
transfer and pump air pressures are set as
desired. See F
IG
. 1 on page 8.
c. If using Automatic Refill, see Automatic Refill
on page 28.
d. If using Manual Refill, see Manual Refill on
page 27.
e. Verify guns are closed.
4. Press to enable the heaters and pump.
NOTE: If using the Schedule function, the heaters and
pump will be enabled automatically at the set time. You
will not need to press if using the Schedule func-
tion unless you wish to enable the heating system
before the set time.
NOTE: When system is up to temperature, the pump will
begin running automatically. It will stall at pressure
unless a gun is open. Material will be dispensed when-
ever a gun is open after the system is up to temperature.
5. When the system is up to temperature, use sepa-
rate gun controller to open and close the guns as
desired to dispense material.
NOTE: While operating the system, the actual tempera-
tures of the hose, gun, and system melter are displayed
on the Home screen.
Shutdown
Press to disable the heaters and pump. The
screen will say “Inactive”. If using the Schedule function,
the heaters and pump will be disabled automatically at
the set time. You will not need to press if using the
Schedule function unless you wish to disable the heat-
ing system before the set time. If the heaters were man-
ually disabled, the Schedule function will automatically
enable them at the next set time.
Do not turn the main power switch OFF if using the
Schedule function.
Schedule
The Schedule function allows the user to specify times
when the system will automatically turn ON and OFF the
heaters and pump.
Set Schedule Times
NOTE: Times are set using a 24-hour clock. Several on
and off times can be set each day.
1. On the Schedule screen (in the Setup screens), set
the ON times for each day of the week.
2. Set the OFF times for each day of the week.