User's Manual

Setup
16 3A2347T
12. Place shaker assembly in an empty adhesive pel-
lets container then fill the container with adhesive
pellets.
NOTE: To promote optimal system performance, pur-
chase 30 Gallon Vibrating Hopper, 24R136. See
installation instructions on page 92.
NOTE: If static buildup on feed tube (G) is excessive,
install optional feed tube ground kit 24R708 to feed tube
end (G6). See F
IG
. 8.
13. Install heated hoses, see F
IG
. 9:
a. Place a rag on the drain tray (W2) attached to
the melter. Residual oil may be in the system
from the factory. See F
IG
. 9.
b. Use a 1/4 in. allen wrench to remove the drain
port plug (W1). See F
IG
. 9.
NOTE: A 1/4 in. allen wrench is shipped loose with the
system.
c. When fluid stops draining, re-install drain port
plug (W1) then remove rag. See F
IG
. 9.
d. Remove plug (247) from the lowest numbered
outlet on the melter. Do not use the drain
plug (W1). See F
IG
. 9.
NOTE: In the following step, the o-ring side of the
hydraulic fitting (68) faces the system. See F
IG
. 9.
e. Install the supplied hydraulic fitting (68) with an
o-ring into the open port and tighten with an
11/16 in. wrench or socket.
f. Install hose onto hydraulic fitting (68) with male
electrical connector side toward the system.
Use 11/16 in. wrench to tighten hose onto
hydraulic fitting (68).
g. Locate MZLP (AA) connector marked with same
number as the hose fluid outlet port. Remove
that connector cover then install connector from
heated hose. See F
IG
. 9.
h. Repeat the procedure for the remaining chan-
nels. Use the bottom melter ports first to ease
installation.
i. Install cap on any unused MZLP electrical con-
nectors.
NOTE: Fluid outlet port 1 must be used and electrical
connector from that hose must be connected to MZLP
connector 1. The system will not operate unless a hose
is connected to MZLP connector 1. If a hose is not con-
nected to connector 1, “Invalid Sensor - hose/gun” faults
will result.
14. Install gun(s), see F
IG
. 9:
NOTE: Use of a Graco gun is not required with this sys-
tem. However, all guns attached to the system must be
rated for 1200 psi (8.3 MPa, 83 bar), 400°F (204°C),
have an RTD type sensor, and use no more than 400W.
a. Connect heated hose fluid outlet to gun fluid
inlet. Use 11/16 in. wrench to tighten. See F
IG
.
9.
b. For Graco guns, attach gun electrical connector
to heated hose electrical connector. See F
IG
. 9.
To reduce the risk of fire and explosion, only use
Graco heated hoses with the InvisiPac system. Use
of non-Graco hoses will void agency approvals.
F
IG
. 9
ti21132a
W2
N
247
68
AA
Gun
W1