User's Manual
Troubleshooting
8 3A2100C
Troubleshooting
Problem Cause Solution
Sight well pumps dry
Low oil level in reservoir Add oil. See Refilling the Reservoir,
page 6.
Pump issue Refer to the Troubleshooting Section
of your pump instruction manual.
No flow from pump outputs
Low oil level in reservoir Add oil. See Refilling the Reservoir,
page 6.
Camshaft not rotating because
rotatory power source is defec-
tive
Replace rotary power source.
Camshaft not rotating because
rotatory power source connec-
tion is defective
Fix rotary power source connection to
lubricator box.
Broken camshaft Replace lubricator box.
Pump issue Refer to the Troubleshooting Section
of your pump instruction manual.
Leaking from under pump Defective gasket Replace gasket.
Leaking from reservoir accessory
plug
Insufficient thread sealant
Clean and replace thread sealant
(user supplied).
Leaking from reservoir drain plug