User's Manual

Installation
3A2100C 7
4. Clean lubricator periodically to eliminate contamina-
tion that may have occurred in the oil. To accomplish
this:
a. Drain reservoir by removing drain plug (C) (F
IG.
1). Dispose of oil according to all applicable
safety regulations.
b. Remove all pumping units.
c. Clean the pumps and reservoir by brushing
loose all foreign matter, dipping in solvent and
blowing dry with compressed air.
d. Replace pumping units. Torque mounting
screws (J) to 110 in. lbs +
10 in. lbs. (12.43 N.m
+
1.13 N.m).
e. Apply thread sealant (user supplied) to drain
plug (C) (F
IG. 1) and replace. Torque to 35 in.
lbs +
5 in. lbs. (3.95 N.m + 0.6 N.m).
f. Fill reservoir. (See Refilling the Reservoir, page
6).