User's Manual
Smart Control Operation
24 3A2090C Operation
6. Press SETUP twice to move to CALIBRATION &
UNITS display. Set TRAVEL DISTANCE to 25 ft
(7.6 m) or longer. Longer distances ensure better
accuracy, depending on conditions.
\
7. Align calibration bar rear edge with 1 foot (30.5 cm)
on steel tape.
8. Push gun trigger control to start calibration.
9. Move striper forward. Keep calibration bar over
steel tape.
10. Stop when calibration bar rear edge aligns with 26
ft. (8 m) on steel tape 25 ft. (7.6 m) distance.
11. Push gun trigger control to complete calibration.
12. NEW CALIBRATION STORED displays. Press
EXIT. Calibration is now complete.
13. Go to MEASURE mode and verify accuracy by
measuring the tape (see MEASURE MODE).
Calibration Error Displays
This message is displayed if striper has rolled beyond
calibration length when gun trigger control is pressed to
end calibration.
This message is displayed if striper has rolled less than
calibration length when gun trigger control is pressed to
end calibration.
!""#
$%&'()