Deviations and Advisories
Therearetwot
ypes of errors that can occur. Errors
are indicated
on the display.
Deviations, indicated by
, require attention, but
not immediately.
Advisories, indicated by
, do not require
attention.
If a deviation or advisory occurs, the system
continues running. The error code and the
or the flash on the screen. If multiple alarms
occur, F2 and F3 have higher priority than MF. They
will appear first and must be cleared first.
Alarm Log Logi
c: If Alarm Auto Clear is enabled,
the system wil
l not log the same alarm twice. For
example, if th
e system fluctuates between low flow
(F2) and acce
ptable flow, the system will log this
error only on
ce, to keep the log from filling up before
the operator
corrects the condition.
If Alarm Auto Clear is not enabled, each alarm will
log only once if the operator corrects the condition
and then clears the alarm. The alarm will log twice
if the operator clears the alarm before correcting the
condition.
The following table explains the error type that is
associated with each error code and icon.
Deviations and Advisories
Icon
and
Code
Description
How to Co
rrect and Clear
F2
Deviation alarm. If enabled, the flow
rate low alarm displays when the
flow rate is lower than the user set
minimum.
Adjust flow rate, reset minimum flow target (see Setup
Screen 2), or disable alarm (see Setup Screen 3).
Press
to clear screen. The alarm will not clear if the
flow rate is still lower than the user set target.
F3
Deviation alarm. If enabled, the flow
rate high alarm displays when the
flow rate is higher than the user set
maximum.
Adjust flow rate, reset maximum flow target (see Setup
Screen 2), or disable alarm (see Setup Screen 3).
Press
to clear alarm. The alarm will not clear if the
flow rate is still higher than the user set target.
MF
Advisory alarm. If enabled, the
maintenance totalizer alarm displays
when the user-set maintenance target
value is reached.
Reset Maintenance Totalizer to zero (see Setup Screen
1). Perform maintenance.
Press
to clear alarm. Alarm will not clear until
Maintenance Totalizer has been reset to zero and no
deviation alarms are occurring.