User's Manual
Technical Data
26 3A1973B
Technical Data
SaniForce 515
US Metric
Maximum fluid working pressure 100 psi 0.7 MPa, 7 bar
Air pressure operating range* 20-100 psi 0.14-0.7 MPa, 1.4-7 bar
Maximum air consumption 28 scfm
0.8 m
3
/minute
Air consumption at 70 psi/20 gpm
18 scfm 0.5 m
3
/minute
Maximum free-flow delivery 16 gpm 61 l/min
Recommended cycle rate for continuous duty 182 cycles per minute
Maximum size pumpable solids 3/32 in. 2.4 mm
Maximum viscosity 10,000 cps
Environmental temperature range 40°–120°F 4°–49°C
Minimum fluid temperature 40°F 4°C
Maximum fluid operating temperature
(Do not exceed the lowest maximum depending on the diaphragm, ball, and seat used in your pump.)
PTFE 220°F 104.4°C
Santoprene® 180°F (82.2°C)
EPDM 275°F (135°C)
Stainless steel 250°F (121.1°C)
Maximum suction lift
Dry
15 ft. 4.6 meters
Wet
25 ft. 7.6 meters
Maximum pump speed
Standard Diaphragms 400 cycles per minute
Overmolded Diaphragms 500 cycles per minute
Fluid flow per cycle*
Standard Diaphragms 0.04 gallons 0.14 liters
Overmolded Diaphragms
0.03 gallons 0.11 liters
Noise (dBa)
Maximum sound pressure
78 dBa @ 70 psi (0.48 MPa, 4.8 bar)
Inlet/Outlet Sizes
Air inlet size
1/4 in. npt(f)
Air exhaust port size
3/8 npt(f)
Fluid inlet size 1.5 in. sanitary flange
Fluid outlet size 1.5 in. sanitary flange