User's Manual

Installation
3A1657F 5
HFR: 3000 Series Flow Meter
1. Perform HFR Pressure Relief Procedure. See
HFR operation manual for detailed instructions.
2. Perform dispense valve Pressure Relief Proce-
dure. See dispense valve manual, page 3, for
detailed instructions.
3. Verify all air, hydraulic, and material pressures have
been relieved before continuing.
4. Perform HFR Shutdown procedure. See HFR oper-
ation manual for detailed instructions.
5. If the flow meter is for the A (Red) side, connect inlet
fitting (2) and outlet fitting (4) to the flow meter. See
F
IG. 1.
If the flow meter is for the B (Blue) side, connect
inlet fitting (3) and outlet fitting (5) to the flow meter.
See F
IG. 1.
NOTE: The connections for each side of the machine
are different sizes to prevent attaching the incorrect
hoses. The A (Red) side has the smaller connections.
6. Connect the flow meter assembly to the fluid
manifold (A) on the HFR system as shown in F
IG. 1.
7. Connect the 3-pin connector (B) on the flow meter
data cable to the flow meter. See F
IG. 1.
8. Route the flow meter data cable as shown in F
IG. 2.
9. Connect the other end of the flow meter data cable
to the fluid control module installed in the electrical
enclosure.
If the data cable is for the A (Red) side flow meter,
connect to port 1 on the FCM. See F
IG. 2.
If the data cable is for the B (Blue) side flow meter,
connect to port 2 on the FCM. See F
IG. 2.
FIG. 1: Flow Meter Installed on Fluid Manifold --
A (Red) side shown
4 or 5
2 or 3
B
A
ti17012a
FIG. 2: Flow Meter Data Cable Routing
FIG. 3: Flow Meter Data Cable Connections
ti17013a
ti17014a