User's Manual

Installation
4 3A1657F
Installation
Flow Meter Electronics Kit
24J318
1. Perform Shutdown procedure. See HFR or NVH
operation manual for detailed instructions.
2. Use two 111800 hex head screws (supplied) to
mount electronics assembly 24J318 to the bottom of
the electrical enclosure. If there are transformers
installed, remove two of the hex head screws from
the transformers and use those two holes to mount
the electronics assembly and discard the supplied
hex head screws.
NOTE: For NVH machines, mount electronics assembly
to the bottom of the “B” side electrical enclosure.
3. Connect CAN cable to CAN connection labeled “1”
on the fluid control module.
4. Connect opposite end of the CAN cable (111) to any
free CAN port on any other fluid control module or
temperature control module in the system. If none
are available, use CAN cables (111 and 113) to con-
nect to CAN splitter inside the power distribution
box. See references on page 20.
ti17009a
ti17010a
ti17011a