Calibration
16 3A1657F
11. Press to dispense a shot to prime the material
lines.
12. Remove container from below the dispense valve.
13. Press repeatedly to select Standby mode.
14. Press to access the Setup screens.
15. Use the arrow keys to navigate to System
screen #3.
16. Press then use the arrow keys to navigate to
the A (Red) and B (Blue) flow meter dropdown
menus.
17. Enter material specific gravity in the A (Red) and B
(Blue) Specific gravity input boxes. This information
may be entered on the System 3 screen, or the Cal-
ibration screen depending on the specific machine
model. See step 23.
18. Use the dropdown menus to select the type of flow
meters installed.
19. Enter 0 in the Alarm % fields. This will prevent
alarms during the calibration dispense that could
prevent dispensing.
20. Select either “RED:1” or “BLUE:1” for the ratio dis-
play.
21. Press to exit the System screen then use the
arrow keys to navigate to the Calibration screen.
22. Press to access the weight calibration and
material specific gravity screen.
23. Enter the material specific gravity in the A (Red) and
B (Blue) specific gravity input boxes.
24. Press to go to the main Calibration screen.