User's Manual

Technical Data
3A1602G 53
Technical Data
Reactor E-8p
US Metric
Maximum fluid working pressure 2000 psi 14 MPa, 138 bar
Electrical requirements Model 259082: 120 Vac, 1 phase, 50/60 Hz, 1800 W;
requires a single dedicated 15 A circuit
Generator Size 2500 W minimum
Maximum Ambient Temperature 110°F 43°C
Maximum Output at 340 cycles/min 12 lb/min 5.4 kg/min
Output per Cycle (A and B) .00352 gal. (.0133 liter)
Overpressure Relief Recirc/Spray valves automatically relieve excessive fluid
pressure back to supply tanks
Sound Pressure
In fast circulation mode
78.7 dB(A)
At 2000 psi (14 MPa, 138 bar), 0.72 gpm (2.7
lpm)
84.5 dB(A)
Sound Pressure per ISO 9614-2
In fast circulation mode
88.6 dB(A)
At 2000 psi (14 MPa, 138 bar), 0.72 gpm (2.7
lpm)
94.4 dB(A)
Inlet/Outlet Sizes
Fluid Outlet - Component A (ISO)
-5 JIC male
Fluid Outlet - Component B(RES)
-6 JIC male
Fluid Circulation Return - Component A (ISO)
-5 JIC male
Fluid Circulation Return - Component B(RES)
-6 JIC male
Air Inlet 1/4 in. quick-disconnect industrial type pin fitting
Air Outlet 1/4 npsm(m)
Hose Markings
A Side Red
B Side
Blue
Weight (empty), without gun and hose
95 lbs. 43.1 kg
Wetted Parts
Aluminum, stainless steel, carbon steel, brass, carbide,
chrome, chemically resistant o-rings, PTFE, ultra-high
molecular weight polyethylene
Maximum Hose Length
105 ft 32 m