Flushing
22 3A1602G
Flushing
• Generally, flush if you will be shut down for more
than 3 days. Flush more often if material is moisture
sensitive and humidity is high in the storage area, or
if material may separate or settle out over time.
• Flush out old fluid with new fluid, or flush out old
fluid with a compatible solvent before introducing
new fluid.
• Use the lowest possible pressure when flushing.
• Always leave some type of fluid in system. Do not
use water.
• For long term storage, flush out the solvent with a
storage fluid such as Bayer Mesamoll plasticizer or,
at minimum, clean motor oil.
1. Engage piston safety lock or trigger safety lock.
Close fluid valves A and B. Leave air on.
2. Set function knob to Stop/Park.
3. Remove both recirculation tubes from material pails
and secure each one to a dedicated waste con-
tainer.
4. Turn Recirc/Spray valves to Recirc.
5. Set function knob to Fast Recirc . Pump mate-
rial from fluid inlet tubes until no more comes out.
6. Set function knob to Stop/Park .
7. Set function knob to Fast Recirc . Pump solvent
through system into waste containers.
8. When nearly clear solvent exits the fluid inlet tubes,
set function knob to Stop/Park
.
NOTE: To flush the spray gun, refer to your separate
spray gun instruction manual.
Flush equipment only in a well-ventilated area. Do
not spray flammable fluids.