Setup
18 3A1602G
7. Set function knob to Slow Recirc or Fast Recirc
.
8. When clean solvent exits both recirculation tubes,
set the function knob to Stop/Park
.
9. Insert inlet tubes into pails. See Connect Fluid
Inlet Tubes, page 18.
10. Set the Recirc/Spray valves to Spray.
11. Run until material exits gun manifold.
Connect Fluid Inlet Tubes
1. Loosen containment knob.
2. Remove suction tube caps and place in containment
tray.
3. Insert each fluid inlet tube through the pour spout on
the appropriate five-gallon pail. Tighten the ring to
the pour spout.
NOTE: Use a drill and mixing blade to mix filled or sepa-
rated materials in the pail before placing fluid inlet tube
into the pail.
FIG. 21
FIG. 22
OR
+
-
+
-
TI17128b
TI17132a
FIG. 23
NOTICE
To prevent cross-contamination of fluids and equip-
ment parts, never interchange component A (isocya-
nate) and component B (resin) parts or containers.
Label one pail “A” and the other “B”, using the red and
blue labels provided. Always double check which
material you have before placing fluid inlet tube into
the pail.