User's Manual
Setup
14 3A1602G
Connect Fluid Hoses
Connect fluid supply hoses to outlet hose connections
(F
IG. 9 and FIG. 10). Red hoses for component A (ISO),
blue for component B (RES). Fittings are sized to pre-
vent connection errors. Connect other end of hoses to A
and B inputs of gun.
NOTE: If using the Recirculation Hose Kit 24M654, con-
nect hoses to Recirculation Gun Manifold Kit 249523.
See F
IG. 10.
Connect Gun to Air Hose
(Air Operated Guns Only)
Connect gun air hose to the gun air input and to the air
filter outlet. If you are using more than one hose bundle,
join the air hoses with the nipple provided with the hose
bundle.
Connect Main Air Supply
NOTE: The Reactor E-8p requires 4 scfm
(0.112 m
3
/min) compressed air for the air operated
spray guns to work correctly.
Connect the main air supply to the quick disconnect fit-
ting on the unit. The air supply hose must be at least
5/16 in. (8 mm) ID up to 50 ft (15 m) or 3/8 in. (10 mm)
ID up to 100 ft (30 m).
Flush Before Using Equipment
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid con-
taminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. See
Flushing, page 22.
FIG. 9: Hose and Air Connections
A (ISO)
B (RES)
A (ISO)
B (RES)
Air
Compressed
Air Line
ti17122a