Operation Programmable Skipline Controller for RoadLazer™ RoadPak™ Line Striping System 3A1215C EN - For the application of road marking reflective materials - For professional use only - Model 24F472 - Controller Only Model 24G632 - Controller, Cable, Remote Switch, and Bracket Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Component Identification and Function Component Identification and Function P N R L T A B C D E SYSTEM DELAY F START SKIP SPACE BEADS ON S BEAD TEST MENU MENU K POWER ON OFF RESET J HOLD PROGRAMMABLE SKIPLINE CONTROL G ti16359a H Switch / Indicator A - F Menu Controls Explanation Provides menu specific commands as display on LCD screen. Provides skipline paint and cycle distance storage for instant change. Press and hold button to store pattern.
Installation Installation Operation Mount Programmable Skipline Control General To reduce the risk of serious injury, mount the Skipline Controller where it is easily visible and will not interfere with your view of the road. It should take no longer to look at the controller than it does to look at a rear-view mirror. To reduce the risk of serious injury, make sure that the Skipline Controller is turned OFF whenever you service any part of the RoadLazer system or leave the RoadLazer unattended.
Operation Menus Information Readout (Startup/Main Menu) Measuring Counter: Resets every time HOLD/RESET is activated. Switch (J) must be in HOLD position See System Delay Example, page 9.
Operation Distance Calibration $ #%.! #/$9 # $ % 5 #/$9 # $ % ! % !/#6 ! # ?! #6 ! $#"% $. $ #%.! #/$9 # $ % # 0$ #@!/ $ #%.! The Distance Calibration Menu is used to calibrate the system against a measured distance (see Distance Calibration Procedure, page 9). 2. Press course. 1. Use adjacent arrows to enter the length of the measured course. 3.
Operation Setup A B C D E F Distance Calibration Pump Calibration Set Gun Delays Setup Marker Layout Mode Diagnostics A Distance Units B GALLONS or LITERS D C Display SPACE or CYCLE D Adjust Display Contrast E Bead Gun Enable/Disable F System Type ti16378b Distance Units Changing units will reset to factory settings A A English B Metric ft/in/mph m/cm/kph C Exit Press A or B to switch English or Metric Units.
Operation Marker Layout Mode # ?! #6 ! $ #%.! #/$9 # $ % 5 #/$9 # $ % ! % !/#6 ! # ?! #6 ! #%" #"!B $#"% $. 1_ ` 4 _)` _ ` _2` _q` _>` _v` _;` { , | 8 !.: q ti16379a NOTE: To operate Marker Layout Mode, you must be in the Marker Layout Mode Menu. Choose a spray gun and toggle that switch to the skipline setting.
Operation Distance Calibration Procedure NOTE: Although the RoadLazer is calibrated prior to shipping, the sensor will need to be recalibrated periodically due to wheel wear, and also whenever the gun-arm wheel is replaced. NOTE: Before recalibrating, ensure that the gun-arm wheel is inflated to 40 psi. and verify the wheel is the proper number of revolutions (see Diagnostics, page 8). 1. Measure and tape off an exact distance up to 1000 ft. Suggested distance is 300 ft - 500 ft.
Operation Example: Painting Two Solid Lines with the One-Operator System Delay™ On B 1. Turn on System Delay. 2. Set guns 1 and 2 in the solid position and the RESET/HOLD switch in the hold position. Reset 1 2 3 Hold ti16401a 3. Align the mechanical reference point with the beginning of the area to be painted (A). 4. Toggle the REST/HOLD button to center and drive the course. This enables the selected guns to begin painting when Point A is reached. Reset 1 2 3 Hold ti16402a 5.
Operation Skipline Applications with One-Operator System Delay™ On 1. Turn on System Delay. C 2. Load the cycle and paint length of the skipline to be painted using the First Menu. 3. Align the mechanical pointer with point A. 4. Set gun 1 to Skip, and toggle the HOLD/RELEASE switch to center. B Reset 1 2 3 Hold ti16399a 5. When the mechanical point reaches point B, set gun 2 to solid . Reset 1 2 3 Hold ti16400a 6. When the mechanical point reaches point C, return gun 2 to center.
Troubleshooting Troubleshooting Problem Control will not turn on. Cause 12 VDC power supply low, or disconnected. Solution Connect the I/O cable. Charge the RoadLazer battery. Check the battery connections. Guns will not spray. Various causes. Toggle RESET on the controller. Check the paint supply. Check the gun ball valves. See manual 306861. Check the RoadLazer and engine fuses. See manual 308611 or 3A1214 and separate engine manual. MPH readout reads zero, or inconsistent reading.
Troubleshooting Control Cable Diagram for RoadPak System Contact 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Description 12 VDC Leave Open - Do Not Connect Leave Open - Do Not Connect Sensor, pump (1) Sensor, pump (2) Paint Gun (1) Solenoid 1 Paint Gun (2) Solenoid 3 Paint Gun (3) Solenoid 5 Bead Gun (1) Solenoid 2 Bead Gun (2) Solenoid 4 Bead Gun (3) Solenoid 6 Engine Shutdown (ground) Ground ** Ground ** Ground ** Sensor Distance Ground ** Leave Open - Do not connect ** All ground pins MUST be connect
Parts Parts 4 BE 1 10 EM ST SY LAY DE SO AD T AR ST IP SK E AC SP BE AD TE N ST F E D ME ME NU NU C B SE RE A T LD HO BE EM ST SY LAY DE S AD T AR ST IP SK E AC SP ON R WE PO N O ST D EA TE B F OF E D ME ME F 10 LE AB OL MM TR RA ON OG E C PR LIN IP SK NU NU C B A RE 3 SE T OLD H R WE PO N O F 6 7 LE AB OL MM TR RA ON OG E C PR LIN IP SK OF 2 ti16360a 5 8 Ref.
Notes Notes 3A1215C 15
Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.