Alarm Troubleshooting
3A1080C 97
E-15: SYSTEM_IDLE_WARNING
Cause Solution
Mix input is high, but the gun has not been triggered for 2
minutes.
If not painting, clear alarm and resume operation.
If painting, shut down and inspect fluid meter.
E-16: SETUP_CHANGE_WARNING
Cause Solution
The system setup parameters have been changed. No action required. See Event Log available through
advanced web interface.
E-17: POWER_ON_WARNING
Cause Solution
The power to the system has been cycled. No action required. See Event Log available through
advanced web interface.
E-18: DEFAULTS_LOADED_WARNING
Cause Solution
The factory defaults have been installed on the system. No action required. See Event Log available through
advanced web interface.
Table 14. Alarm Troubleshooting