User's Manual
Table Of Contents
- Related Manuals
- Equipment Approvals
- System Configuration and Part Numbers
- Warnings
- Important Two-Component Material Information
- Glossary of Terms
- Overview
- EasyKey Display and Keyboard
- Run Mode Screens
- Setup Mode
- ProControl 1KS Integration Specifics
- System Operation
- Meter Calibration
- Color Change
- Alarms and Warnings
- Alarm Troubleshooting
- Schematic Diagrams
- Technical Data
- Graco Standard Warranty
- Graco Information

Color Change
88 3A1080C
FIG. 92: Color Change Chart 15
V
alve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A
Catalyst Change B Air Chop Time B
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Purge
Dispense A AA
Dispense B BB
Gun Trigger(s) by Operator
01 23 4
First Purge Time 0->1
Chop Time (air/solvent or air/3rd flush) 1->2
Final Purge Time 2->3
Mixed Fill Time 3->4
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
ProMix 2KS Recipe Change
Chart 15: Same A, Same B
FIG. 93: Color Change Chart 16
V
alve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A
Catalyst Change B Air Chop Time
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Purge
Dispense A AA
Dispense B BB
Gun Trigger(s) by Operator
01 234 5
First Purge Time 0->1
Chop Time (air/solvent or air/3rd flush) 1->2
Final Purge Time 2->3
Wait for External Color Change Ready signal
(before advance to step 4) 3->4
Mixed Fill Time 4->5
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
Recipe Change Purge Active Output
Recipe Change Fill Active Output
ProMix 2KS Recipe Change
Chart 16: External Color Change Option