User's Manual

Color Change
3A1080C 87
FIG. 90: Color Change Chart 13
V
alve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A A
Catalyst Change B
Air Purge
Solvent Purge
3rd Flush Purge
Dispense A A A A
Dispense B B B
Gun Trigger(s) by Operator
01 2
Color Fill Time 0->1
Mixed Fill Time 1->2
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
ProMix 2KS Recipe Change
Chart 13: Recipe 0 OR 61 to Recipe X without Dump Valves
FIG. 91: Color Change Chart 14
V
alve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A
Catalyst Change B B
P0 P1 P2 P3 P4
Color Purge Time P0->P1
Color Fill Time P1->P2
Catalyst Purge Time P2->P3
Catalyst Fill Time P3->P4
Air Chop Time
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Valve
Dispense A AA
Dispense B BB
Gun Trigger(s) by Operator
M0 M1 M2 M3 M4
First Purge Time M0->M1
Chop Time (air/solvent or air/3rd flush) M1->M2
Final Purge Time M2->M3
Mixed Fill Time M3->M4
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
1st On/Start 1st On Length/Duration 2nd On/Start 2nd On Length
Special Output #1
Special Output #2
Special Output #3
Special Output #4
Recipe Change Purge Active Output
Recipe Change Fill Active Output
B
A
CC Purge/Fill Timers are independent
of Mixed Material Purge Timers. This
line defines when the Mixed Fill Time
begins. The longer of the two timers
defines when the Mixed Fill Time
begins.
ProMix 2KS Recipe Change
Chart 14: A1 to A2, B1 to B2 with All
A
B