User's Manual
Table Of Contents
- Related Manuals
- Equipment Approvals
- System Configuration and Part Numbers
- Warnings
- Important Two-Component Material Information
- Glossary of Terms
- Overview
- EasyKey Display and Keyboard
- Run Mode Screens
- Setup Mode
- ProControl 1KS Integration Specifics
- System Operation
- Meter Calibration
- Color Change
- Alarms and Warnings
- Alarm Troubleshooting
- Schematic Diagrams
- Technical Data
- Graco Standard Warranty
- Graco Information

Color Change
86 3A1080C
FIG. 88: Color Change Chart 11
V
alve Time-Sequence
Dump A A
Dump B B
Color Change Solvent
Catalyst Change Solvent
Color Change A A A
Catalyst Change B B B
Air Purge
Solvent Purge
3rd Flush Purge
Dispense A A A
Dispense B BB
Gun Trigger(s) by Operator
012 3
Color Fill Time 0->1
Catalyst Fill Time 1->2
Mixed Fill Time 2->3
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
ProMix 2KS Recipe Change
Chart 11: Recipe 0 OR 61 to Recipe X with Dump Valves
FIG. 89: Color Change Chart 12
V
alve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A
Catalyst Change B Air Chop Time
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Valve
Dispense A A
Dispense B
Gun Trigger(s) by Operator
01 2 3 4
Color Purge Time 0->1
First Purge Time 1->2
Chop Time (air/solvent or air/3rd flush) 2->3
Final Purge Time 3->4
Notes:
All timing from Recipe 0
Chart 12: Recipe X, 0, OR 61 to Recipe 0 without Dump Valves
ProMix 2KS Recipe Change