User's Manual

Color Change
82 3A1080C
FIG. 80: Color Change Chart 3
V
alve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A
Catalyst Change B B
P0 P1 P2 P3 P4
Color Purge Time P0->P1
Color Fill Time P1->P2
Air Chop Time
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Valve
Dispense A AA
Dispense B BB
Gun Trigger(s) by Operator
M0 M1 M2 M3 M4
First Purge Time M0->M1
Chop Time (air/solvent or air/3rd flush) M1->M2
Final Purge Time M2->M3
Mixed Fill Time M3->M4
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
ProMix 2KS Recipe Change
Chart 3: A1 to A2, same B with Dump Valves
CC Purge/Fill Timers are independent
of Mixed Material Purge Timers. This
line defines when the Mixed Fill Time
begins. The longer of the two timers
defines when the Mixed Fill Time
begins.
A
A
FIG. 81: Color Change Chart 4
V
alve Time-Sequence
Dump A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A A
Catalyst Change B Air Chop Time B
Solvent Chop Time
First Purge (one of these) 3rd Flush Chop Time
Air Purge
Solvent Purge Final Purge (one of these)
3rd Flush Valve
Dispense A A AA
Dispense B BB
Gun Trigger(s) by Operator
012 3 4 5 6
Color Purge Time 0->1
Color Fill Time 1->2
First Purge Time 2->3
Chop Time (air/solvent or air/3rd flush) 3->4
Final Purge Time 4->5
Mixed Fill Time 5->6
Notes: Load tables from new recipe
Purge from old recipe
Fill from new recipe
Chart 4: A1-A2, same B without Dump Valves
ProMix 2KS Recipe Change