Meter Calibration
3A1080C 77
8. Compare the amounts on the EasyKey to the
amount in the beaker.
NOTE: For maximum accuracy, use a gravimetric
(mass) method to determine the actual volume dis-
pensed.
9. If the screen and actual volume are different, enter
the actual dispensed volume in cc for A or Solvent
Volume field, and press the Enter key
.
If the value was substantially different, repeat the
calibration process.
NOTE: If the screen and actual volume is the same
or if for any reason you want to cancel the calibra-
tion procedure, scroll to Abort on the Calibration
Screen menu and press the Enter key
.
10. After the volume for A or Solvent is entered, the Pro-
Control 1KS controller calculates the new flow meter
K-Factor and shows it on the Calibration Screen.
NOTE: K-Factor values on the screen are viewable
only. If needed, you can manually edit the K-Factors
in Advanced Setup Screen 4 (page 37) or Recipe
Setup Screen 5 (page 42).
11. Before you begin production, clear the system of
solvent and prime it with material.
a. Go to Mix mode.
b. Trigger the gun into a grounded metal pail until
mixed material flows from the gun nozzle.
c. To begin operation, see Start Up, page 67.