System Operation
66 3A1080C
Mix Manifold Valve Settings
To open dose or purge valves, turn hex nut (E) counter-
clockwise. To close, turn clockwise. See Table 10 and
F
IG. 70.
F
IG. 70. Valve Adjustment
E
TI11581a
Table 10: Mix Manifold Valve Settings
Valve Setting Function
Dose (see
F
IG. 70)
Hex nut (E) 1-1/4 turns out
from fully closed
Limits maximum fluid flow rate into integrator
and minimizes valve response time.
Purge (see
F
IG. 70)
Hex nut (E) 1-1/4 turns out
from fully closed
Limits maximum fluid flow rate into integrator
and minimizes valve response time.