ProControl 1KS Integration Specifics
3A1080C 55
NOTE: Shaded cells relate to the flow charts on pages 50-54.
Table 5: ProControl 1KS Digital Inputs (Modbus Register 40040)
Bit Digital Input Binary Name Details
0:5 0000000000XXXXXXRecipe Binary bits for viewing discrete inputs only.
6 000000000
1000000Color Change
(CC)
Set bit to “1” to initiate Color Change (momentary)
7 00000000
10000000Mix Set bit initiate Mix mode (maintain)
8 0000000
100000000Purge Set bit to “1” to initiate Purge sequence (maintained)
9 0000001000000000Job_Complete Set bit to “1” to initiate Job Complete input (momen-
tary)
10 0000010000000000External CC
Ready
Set bit to “1” to initiate External Color Change
(momentary)
11 0000100000000000Not Used
12 0001000000000000FC _Calibrate Set bit to “1” to initiate a Flow Control Calibrate input
(momentary)
13 0010000000000000Gun_Trigger Set bit to “1” to indicate the gun is actually triggered
(maintain while gun is triggered, remove when gun is
closed)
14 0
100000000000000Reset_Alarm Set bit to “1” to clear an active Alarm (momentary)
15 1000000000000000Remote Stop Set bit to remotely stop unit (momentary)