Setup Mode
44 3A1080C
Recipe 0 Screen 3
This screen only appears if Solvent Monitor is set to
“Meter” in Configure Screen 5, page 31 and Flush Vol-
ume Check is set to “On” in Option Screen 1, page 32
or 3rd Flush Valve is set to “On” in Configure Screen 3
on page 30.
Minimum Flush Volume
This field only appears if Flush Volume Check is set to
“On” in Option Screen 1 on page 32. Enter the mini-
mum flush volume (0 to 999 cc).
Exiting Fill Source
This field only appears if 3rd Flush Valve is set to “On” in
Configure Screen 3 on page 30. Select “Off,” “Air,” “Sol-
vent,” or “3rd Valve.”
Exiting Fill Time
This field only appears if Exiting Fill Source is set to
“Air,” “Solvent,” or “3rd Valve.” Enter the time in seconds.
Recipe 0 Screen 4
This screen appears only if Flush and Fill Input is set to
“Recipe” in Option Screen 1, page 32 and Special Out-
puts is set to 1, 2, 3, or 4 in Configure Screen 5, page
31. The I/O board has four programmable outputs.
Calibration Screen
Use this screen to calibrate a meter. Set to “Meter A,”
“Meter B,” or “Solvent Meter” (available if Solvent Moni-
tor in Configure Screen 5, page 31, is set to “Meter”).
• Start - start calibration
• Abort - stop calibration
• Purge - purge sampling valves after calibration
See Meter Calibration, page 76, for when and how to
calibrate meter.
F
IG. 55. Recipe 0 Screen 3
FIG. 56. Recipe 0 Screen 4
F
IG. 57. Calibration Screen