User's Manual

Setup Mode
30 3A1080C
Configure Screen 3
Run Mode
Select the Run mode application from the pulldown
menu: Automatic (default), Semi-Automatic (uses a
manual spray gun), or Manual.
Dump Valve A
This field only appears if the system includes an optional
dump valve A. If dump valve A is included, set to On.
Dump Valve B
This field only appears if the catalyst change option is
detected from the cc board, meaning that dump valve B
is present. On is the only setting.
3rd Flush Valve
Off is default. If optional 3rd flush valve is used, set to
On.
Configure Screen 4
Dose Size
Select the total dose size (cc) from the pulldown menu:
100, 50, 25, or 10. The DD selection (dynamic dosing) is
not used with the ProControl 1KS.
Dose Time Alarm
Enter the dose time (1 to 99 seconds). This is the
amount of time allowed for a dose to occur before a
dose time alarm occurs.
Number of Guns
Enter the number of spray guns (1 or 2).
NOTE: Only 1 gun is used in automatic mode.
Gun Flush Box (manual or semi-automatic mode)
Enter the number of gun flush boxes (Off, 1, or 2).
F
IG. 29. Configure Screen 3
OR
FIG. 30. Configure Screen 4