User's Manual
Instructions
3A0533D 3
4. Tighten pump element buy hand and then torque to
50 in. lbs (5.6 N•m) (F
IG. 3).
Adjusting Output Volume
NOTE:
• It may be necessary to repeat the outlet volume
setup procedure after the pump is operating to
re-adjust the volume of dispensed grease.
• The amount of dispensed volume can vary depend-
ing on external conditions such as lubricant temper-
ature and back pressure from downstream
connections. Use the volume adjustments provided
in Table 1 as a starting point and adjust as neces-
sary to ensure desired lubrication dispense.
1. Use a wrench to turn pump element counter-clock-
wise to loosen.
2. If needed, remove or insert spacers to achieve
required pump output volume.
• Pump volume control is set using either no (0)
spacers, 1 or 2 spacers (F
IG. 4).
• Do not use more than 2 spacers on any pump
element.
Table 1: Output Volume
F
IG. 3
No. Spacers
Output Volume / Minute
cubic inches cubic cm
00.2474.0
10.182 3.0
20.1172.0
F
IG. 4