User's Manual

Instructions
3A0523C 3
left side of the G3 pump (b) (when viewed from the
front) (F
IG. 4).
9. Leave banjo bolts loose enough for banjo fitting to
swivel.
10. Install tube (1) between the two banjo fittings. It may
be necessary to loosen the banjo fitting to install this
tube (F
IG. 5).
11. Tighten tube nuts (3), wrench tight only.
12. Tighten banjo bolts (6) to 35 ft. pounds (45.7 N•m)
at each location.
13. Apply thread sealant to threads of plug (10). Install
plug in unused outlet location (F
IG. 6).
Kit 571026 - 3 Pump Outlets
1. Disconnect power to G3.
2. If unit has been in service, relieve pressure, page 2.
3. Loosely assemble tube nut (3), tube ferrule (4) and
tube fitting (5) (F
IG. 2).
4. Apply thread sealant to threads of tube fittings (a)
(F
IG. 3).
5. Connect one tube fitting assembly (3/4/5) to each
banjo fitting (9). Wrench tighten (F
IG. 3).
6. Place one washer (8) over the end of the dual banjo
bolt (7). Then install banjo fitting (9) on bolt. Install
another washer (8) followed by another banjo fitting
(9) and then one more washer (8) in the orientation
shown in F
IG. 7.
7. Install this assembly into the pump element (c)
located on the right side (viewed from the front) on
the G3. Leave bolt loose enough for banjo fitting to
swivel (F
IG. 8).
8. Place one washer (8) over the end of each banjo
bolt (6) (F
IG. 3).
9. Install banjo bolts (6) into banjo fittings (9). Then
install second washer (F
IG. 3).
FIG. 4
FIG. 5
F
IG. 6
c
b
1
3
10
F
IG. 7
F
IG. 8
8
9
8
9
8
7
c
d
b