User's Manual
Installation and Setup
3A0418E 9
12.If counter pressure is 4 bar (58 psi) or
higher, flush lubrication point with a grease
gun.
After flushing, repeat counter pressure test.
If the counter pressure does not decrease
you may need a different lubricant or lubri-
cator canister. Contact Graco Customer
service for assistance.
Grounding Clamp Installation
EC-120 Models Only
1. Insert lubrication canister inside grounding
clamp (1) making sure bottom of canister is
flush mounted to the grounding clamp as
shown in FIG. 3.
2. Attach a grounding cable (2) between the
grounding bracket (1) and an earth contact
(3) as shown in FIG. 3.
To reduce the risk of fire or explosion, equip-
ment mounted in potentially explosive atmo-
spheres must be correctly installed using a
grounding clamp. Part No. 124304 is available
from Graco Customer Service or your local
Graco distributor.