User's Manual

Installation and Setup
3A0418E 13
Startup
NOTE:
The lubrication period is determined by
the color of the activator screw.
Electrochemical lubricators are tempera-
ture and vibration dependent.
Refer to Table 1 to determine the correct acti-
vator screw and lubricator to use for your appli-
cation and operating temperature. The data
provided in this table is based on laboratory
tests and under laboratory conditions and
should be used as a general guideline only for
selecting the discharge period. The actual dis-
charge period is strongly influenced by various
factors including the type of lubricant, ambient
temperature, vibration and connection parts.
Table 1: EP-120 and EC-120 Lubricators*
*Initial delay = approximately 1 day. (Time required until first lubricant discharge takes place with-
out counter pressure.)
1 month 3 months 6 months 12 months
Activator
Screw Color
Yellow Green Red Gray
Average
Temperature
Discharge
Period
(Months)
cc / Day
Discharge
Period
(Months)
cc / Day
Discharge
Period
(Months)
cc / Day
Discharge
Period
(Months)
cc / Day
0°C / +32°F
4 1 8 0.5150.3>18<0.2
+10°C / +50°F
2250.880.5180.2
+20°C / +68°F
1431360.7120.3
+30°C / +86°F
0.852231.360.7
+40°C / +104°F
0.66.7142231.7