User's Manual
Troubleshooting
22 3A0417D
Troubleshooting
Malfunction Possible Cause Solution
Lubricator does not function
Wrong cable connection
Connect cable according to pin
assignment (page 6). Check pin
assignment.
Break in cable
Check voltage at plug. Attach
new cable.
No power supply
Check power supply. Make sure
there is sufficient power avail-
able for the number of lubrica-
tors used.
Relay defect in machine Change relays.
Lubricator signals “system func-
tions OK” (green LED), although
lubrication canister is empty
Setting of VOL switch different
than attached lubrication canis-
ter
Replace with full lubrication can-
ister
Partly filled lubrication canister
was replaced by an almost
empty lubrication canister
Lubricator signals “system mal-
functions” (red LED)
Clogged tube and/or connection
parts
Clean tube and connecting
parts, then shut off and restart
lubricator.
Counter pressure too high
Lubricator discharges too fast
Wrong position of VOL or TIME
switch
Replace lubrication canister with
a full lubrication canister
Set dip switches to correct set-
ting.
Lubricator signals “end of dis-
charge” (red and green LED)
although the unit is not empty
Setting of VOL switch different
than attached lubrication canis-
ter
Replace with full lubrication can-
ister.
Almost empty lubrication canis-
ter was replaced with a partially
filled canister
Reset peg was not pushed down
during assembly
Move drive unit a few teeth so
reset peg is pushed down.
Lubricator does not discharge
the correct amount
Dip switch setting was done
incorrect
Replace lubrication canister with
a full lubrication canister
Set dip switches to correct set-
ting.