User's Manual

Installation and Setup
18 3A0417D
Installing Lubricator to
Lubrication Point
1. Clean the lubrication point to remove any
potential contaminants.
2. Verify the thread of the lubricator corre-
sponds to the thread of the screw point.
3. Install reducers, extensions, grease line,
etc. (if necessary).
4. Verify Dip Switches are correctly set. See
Table 1, page 13.
5. Prime the grease line and all accessories
with the same grease that is contained in
the lubricator. (See Parts, page 23 for a
complete list of available grease car-
tridges).
6. Remove the plug (A).
7. Install lubricator unit
into adapter (B).
8. Screw lubricator to lubrication point, hand
tight only.
A
B
NOTICE
To ensure optimal lubrication:
Seal threads of all connecting parts with a
suitable, standard sealant.
Mount oil filled lubricators properly with the
outlet pointing down.
Never screw in the lubricator a second time
or the self-sealing threads will be dam-
aged.
For remote mounting installations, make
sure bracket does not squeeze the lubrica-
tion canister as this could block the piston
inside the canister.