User's Manual

Installation and Setup
3A0417D 13
TABLE 1: Dip Switch Settings
Amount of discharge in cc (1cc = 0.9 gram lubricant) per 100 operating hours.
White square indicates position of dip switch.
Determining proper dip switch settings to achieve optimal lubrication
In the “normal mode” (per 100 operating
hours).
Example:
A roller bearing is to be provided with 14 cc of
lubricant every 500 hours of operation: 14 cc 
500 hours = 0.028 cc per hour = 2.8 cc per 100
hours.
Table 1 shows the 3 different settings that are
possible for each lubrication canister size.
Variation 1: 2.78 cc/100
hours for a 60 cc Lubrication
canister (EM-60).
Variation 2: 2.78 cc/100
hours for a 120 cc Lubrication
canister (EM-120).
Variation 3: 2.89 cc/100
hours for a 250 cc Lubrication
canister (EM-250).
Canister
Size
EM-60 EM-120 EM-250
Discharge period
Dip Switch
Position
8.33 16.67 34.72 1 month continuous operation
2.78 5.56 11.57 3 months continuous operation
1.39 2.78 5.79 6 months continuous operation
0.69 1.39 2.89 12 months continuous operation