User's Manual
Changing the Lubrication Canister
20 3A0416C
Installing New Lubrication Canister
1. If a different size lubrication canister or dis-
charge period is going to be used, change
dip switches to reflect the new canister size
and/or impulse change. See Table 1, page
13.
2. Place drive unit on top of new lubrication
canister until the teeth of both pieces are
locked.
3. Screw the cover of the drive unit onto the
lubrication canister - hand tighten only.
4. Remove plug (A) from
bottom of lubrication
canister.
5. Install lubricator unit into adapter (B).
6. Screw lubricator into the lubrication point -
hand tighten only. DO NOT screw it in a
second time.
7. For oil filled lubricators, make sure the
lubricator is installed vertically (outlet point-
ing down).
8. Plug cable back into lubricator (FIG. 10).
9. The control will wait for a pulse to start dis-
charging.
Lubrication Canister Disposal
Dispose of hazardous fluid in approved con-
tainers, and according to applicable guide-
lines. Read the MSDS to know the specific
hazards of the fluids you are using.
Storage
When lubricators are not immediately installed,
they must be stored in a dry, dust free, sunlight
protected room, indoors.
NOTICE
Never screw in the lubricator a second time
or the self-sealing threads will be damaged.
A
FIG. 10