User's Manual

Installation and Setup
14 3A0416C
Selecting Mounting Location
Installation Guidelines
Before installing the lubricator, the lubrica-
tion points and any extensions must be
adequately pre-lubricated with the same
lubricant contained in the lubricator. A 400
gram lubricant cartridge for grease guns is
available from Graco. See Parts, page 22
for a complete list of available lubricant car-
tridges.
Install one lubricator per lubrication point.
When oil is used for lubrication, a
non-return valve (oil throttle) must be
installed. This will prevent oil leakage from
the lubricator. An oil throttle, part number
124102 is available from Graco. See Parts,
page 22.
An oil-filled lubricator must be installed ver-
tically (outlet down).
For horizontal mounting a bracket clip must
be used to hold the lubricator in place. A
horizontal clip bracket part number 124086
is available from Graco. See Parts, page
22
For vertical installations always use a sup-
port adapter part number 124105 is avail-
able from Graco. See Parts, page 22.
The grease nozzle of the lubricator has a
npt 1/4 inch male thread. If your application
has a different thread you may need to use
an adapter. See Parts, page 22 for a com-
plete list of available adapters.
Do not overtighten the plastic thread of the
lubricator.
For all metal to metal connections (i.e.,
extensions, reducers, etc.) make sure to
use LOCTITE
®
243* (semi-tight screw lock-
ing).
*Loctite
®
is a registered trademark of the Loctite Corpo-
ration.
Direct Mounting Installation
Refer to FIG. 4 for examples of correct and
incorrect direct mounting installations.
FIG. 4
Correct
Incorrect