User's Manual
Errors
3A0294G 69
Deviations
DF
Diving Up Red Flash-
ing
Pump leaking during up stroke. Replace worn piston valve or
packings.
DG
Diving Down Red Flash-
ing
Pump leaking during down
stroke.
Replace worn intake valve or
priming rod seal.
Advisories
B2
Shot Volume
Less than Advi-
sory Setpoint
Yellow
Solid
Shot volume is less than the
advisory setpoint.
Increase the advisory setpoint on
Setup screen 11. Increase shot
consistency by decreasing
speed and valve shutoff time,
and increasing material
back-pressure.
B3
Shot Volume
Greater than
Advisory Set-
point
Yellow
Solid
Shot volume is greater than the
advisory setpoint.
Increase the advisory setpoint on
Setup screen 11. Increase shot
consistency by decreasing
speed and valve shutoff time,
and increasing material
back-pressure.
B9
Inconsistent
Shot
Yellow
Solid
A possible inconsistent shot
caused by a shot volume less
than overshoot.
Request a larger shot.
Verify that shot volume variation
is okay.
L2
Drum Low Yellow
Solid
Drum low empty sensor has
tripped.
Replace empty drum with a full
drum.
MA
Maintenance
Counter
Yellow
Solid
Maintenance counter has
expired. Maintenance counter
has counted down to 0 from set-
point.
Volume specified by setpoint has
passed since last reset.
Code Icon Code Name
Light
Tower
Code
Cause Solution