User's Manual

Errors
66 3A0294G
Errors
From the Run screen, press to navigate to
the Information screen. The Information screen displays
the current alarm or advisory, and the amount of remain-
ing material in the drum.
Alarms, indicated by , require immediate attention;
therefore, the system disables and the Information
screen automatically displays. Deviations, indicated by
, require attention, but not immediately. Advisories,
indicated by , do not require attention. Therefore, if
a deviation or advisory occur, the system continues run-
ning and or displays next to the operation
mode field.
Errors with Light Tower
If you have a system that uses a light tower, errors are
indicated by the light tower as well as on the display. The
following table explains the error type that is associated
with the particular light tower LED.
Clear Errors
To clear an error:
1. Press to access the fields.
2. Press to navigate to the error code
reset field.
3. Highlight the error code. Press to clear the
error code.
4. Press to exit edit mode
Light Tower LED Description
No LED No errors exist
Yellow Solid
An advisory exists
Red Flashing
A deviation exists
Red Solid An alarm exists and the system