User's Manual

Operation
62 3A0294G
Operation
NOTE: The shot dispense kit controller modifies pump
packages and supply systems. However, the operation
procedures from the pump packages instructions-parts
manuals and the Supply Systems Operation manual still
apply.
Startup
1. Refer to your Supply System Operation manual or
pump package instruction-parts manual for system
startup instructions.
2. Turn on the user interface display and wait for the
power up screen to complete and the run screen to
appear.
Change Operation Mode
There are four operation modes: shot mode, sequence
mode, manual mode, and park mode. This section
explains each operation mode. See , page 92, for more
details about the operation modes and the run screens.
Use the following instructions to change between opera-
tion modes.
1. Press to access fields to make changes.
2. Press to navigate to the operation
mode field.
3. Press to enter operation mode field.
4. Press to scroll through the operation
mode choices.
5. Press to select the desired operation mode.
6. Press to exit edit mode.
Shot Mode
Shot mode dispenses a specific volume or weight of
material. When the shot completes the user can start
another identical shot. Shots first need to be defined in
setup screen 1. Up to 25 shots can be programmed.
See Define Shot Size, page 54.