User's Manual

Set System Parameters
3A0294G 61
9. Remove any excess material from the dispense
valve, if necessary. Include this material in the
weight of the shot.
10. Weigh the shot on the scale.
11. Press and to enter the shot
weight in the weight field.
12. Set the scale to zero.
13. Perform steps 1-6 three more times.
After you have entered the fourth shot weight in the
weight field, the material delta top and bottom fields
(calibration values) will automatically update and the
specific weight on setup screen 1 will update. The
calibration procedure is now complete.
Set Shot Accuracy Errors
Use this screen to set the shot volume deviation from
the shot setpoint that will cause an advisory or alarm.
NOTE: If either the advisory field or alarm field is set to
zero, the error is disabled.
1. Navigate to setup screen 11.
2. Press to access fields to make changes.
3. Press to navigate to the advisory field.
4. Press to enter the advisory field.
5. Press and to set the value in the
advisory field.
6. Press to enter the value.
7. Follow steps 4 through 7 for the alarm field.
8. Press to exit edit mode.