User's Manual
Set System Parameters
60 3A0294G
Calibrate
The actual weight/volume of material dispensed may
vary slightly from the displayed weight/volume. Use the
following procedure to calibrate the system as needed.
Calibration values can be set manually. However, it is
recommended to run the calibration procedure when
needed.
1. Navigate to setup screen 10.
2. Press to start the overshoot calibration pro-
cess. The icons will display.
3. Place a container that is at least as large as the
pump volume under the dispense valve.
4. Hold down or the foot switch to run the sys-
tem. The manual mode icon will flash. The pump will
go through the first changeover, stop to measure the
overshoot, then complete the second changeover
and stop.
5. Release the start button or foot switch. The hour
glass icon is updated and the shot mode icon will
display.
6. Remove any excess material from the dispense
valve, if necessary.
7. Empty the container, if necessary. Set the scale to
zero.
8. Press to dispense a shot into the container.
When the shot completes the shot icon will disap-
pear and the first digit of the weight field will be high-
lighted.