User's Manual

Set System Parameters
3A0294G 59
Set Pump Runaway Error
1. Navigate to setup screen 7.
2. Press to access fields to make changes.
3. Press to navigate to the pump runaway
cycle rate field.
4. Press and to increment or decre-
ment to the desired cycle rate. Graco recommends
setting the cycle rate to 60 or less. Choose a value
that is just above the maximum cycle rate of the
application.
5. Press to save the set cycle rate.
6. Press to exit edit mode.
Set Maintenance Parameters
Set the amounts of material moved through the pump
and dosing valve that will result in a maintenance advi-
sory or alarm.
1. Navigate to setup screen 8.
2. Press to access fields to make changes.
3. Press to navigate to the maintenance
setpoint field.
4. Press and to increment or decre-
ment to the desired amount of material that will
result in an advisory when the total volume dis-
pensed exceeds the maintenance setpoint.
5. Press to save this amount.
6. If an advisory occurs, press to navigate to the
total volume dispensed field. Clear the field to reset
the advisory.
7. Press to exit edit mode.
Maintenance
Total Volume
Dispensed
Setpoint