User's Manual
Installation
48 3A0294G
11. Install the pressure sensor on the pump bleed port.
a. Use a wrench to remove the pressure valve.
b. Apply the supplied sealant to the adapter (42),
the manifold (43), and the pressure valve. Install
all three in the order listed.
c. Disconnect pressure sensor at PT1.
d. Install the o-ring (45) and pressure sensor (44).
See F
IG. 95.
12. Bundle the cables and zip tie them close to the elec-
tronics bracket (1) so that they will fit under the elec-
tronics subassembly cover (4).
13. Install the air lines (34).
a. Connect the air lines to the valve subassembly
(6) as shown.
b. Run the air lines between the adapter bracket
and connect them to the top port and bottom
port of the solenoid valve assembly as shown.
See F
IG. 96 and FIG. 97.
c. Zip tie both air lines to the pump tie rod.
FIG. 94: Remove Pressure Valve
FIG. 95: Install Pressure Sensor
Pressure Valve
Pressure
Valve
44
42
43
45
FIG. 96: Install Air Lines - Air Valve
FIG. 97: Install Air Lines - Solenoid Valve
Plugged
r_262375_3A0294_41a
Top Po r t
Bottom Port