User's Manual

Installation
38 3A0294G
c. Loosely install the air valve assembly (3)
Remove air pressure gauge if necessary.
Grease the o-ring included with the air valve
assembly. Install the o-ring and then finish
installing the air valve assembly. Secure with the
two screws that are included with the air valve
assembly.
d. Install the new air motor slider valve label that is
included with the air valve assembly.
e. If removed, coat the gauge fitting and elbow fit-
ting with PTFE tape, and then reinstall. Use a
wrench to tighten.
f. Install the fitting and air hose on the back of the
new air valve assembly. Use two wrenches to
tighten.
5. Install the linear sensor (17).
a. Remove the lift ring or plug.
b. Insert magnet holder and magnet into the top of
the motor shaft using the magnet installation
tool.
c. Install the linear sensor assembly into the top
plate of the air motor.
6. Install the reed switch assembly (19).
a. Remove the air line to the motor.
b. Adjust the air fitting to make room for the reed
switch (19).
c. Install the reed switch into the air valve as
shown in F
IG. 41, and secure with the screw
(20).
FIG. 70: Install Air Valve Assembly
FIG. 71: Install Fitting
Screw
Slider Valve
O-ring
3
r_262374_3A0294_68a
Label
Fitting
r_262374_3A0294_69a
FIG. 72: Install Linear Sensor
ti18237a
17
Magnet
Magnet
Holder
Motor
Shaft